Test Item Test Method
Mechanical Performance Tests:
Leakage test Fine Leak: Should be less than 5x10-8 atmCC/secby
holium leak detector.
Gross Leak: Should be immersed in hot water(90¡Ó5¢J)for 5 Minutes resulting no buble generated around it.
Shock test Orient the sample in any attitude and drop it three times from a height of 50cm onto a hardwood board with a thickness of 3cm.
Resistance to soldering heat Dip terminal in a 260¡Ó5¢J solder bath for 10¡Ó0.5 seconds The solder shell leave an undipped lead an undipped terminal length og 2mm at their base.
Bending strength Apply a 500g load to one of the terminals, and after tilting the unit Resonator for 90¢X,restore to its original attitude. The tilt it in an opposite direction for 90¢X and restore to its original attitude.
Lapping Precision Lapping To lap a quartz crystal to the extent of the prescribed thickness and frequency.
Tensile strength After pasting together the thickness lapped quartz crystal, process them to the prescribed dimensions.
Beveling Apply a 1.5kg tensile load to terminal and sustain it for 30¡Ó5 seconds.
Environmental Tests:
Storage In Low Temperature Expose the sample in an inoperative mode to 500 hours in a -40¢J Environment.
Storage In High Temperature Expose the sample in an inoperative mode to 500 hours of a +85¢J Environment.